Sci Rep ; 14(1): 6393, 2024 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493258

RESUMO

The use of mobile head CT scanners in the neurointensive care unit (NICU) saves time for patients and NICU staff and can reduce transport-related mishaps, but the reduced image quality of previous mobile scanners has prevented their widespread clinical use. This study compares the image quality of SOMATOM On.Site (Siemens Healthineers, Erlangen, Germany), a state-of-the-art mobile head CT scanner, and a conventional 64-slice stationary CT scanner. The study included 40 patients who underwent head scans with both mobile and stationary scanners. Gray and white matter signal and noise were measured at predefined locations on axial slices, and signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated. Artifacts below the cranial calvaria and in the posterior fossa were also measured. In addition, image quality was subjectively assessed by two radiologists in terms of corticomedullary differentiation, subcalvarial space, skull artifacts, and image noise. Quantitative measurements showed significantly higher image quality of the stationary CT scanner in terms of noise, SNR and CNR of gray and white matter. Artifacts measured in the posterior fossa were higher with the mobile CT scanner, but subcalvarial artifacts were comparable. Subjective image quality was rated similarly by two radiologists for both scanners in all domains except image noise, which was better for stationary CT scans. The image quality of the SOMATOM On.Site for brain scans is inferior to that of the conventional stationary scanner, but appears to be adequate for daily use in a clinical setting based on subjective ratings.


Assuntos
Tomografia Computadorizada por Raios X , Substância Branca , Humanos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Cabeça/diagnóstico por imagem , Crânio/diagnóstico por imagem , Doses de Radiação
3.
Radiat Prot Dosimetry ; 200(6): 564-571, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38453140

RESUMO

The International Atomic Energy Agency, as part of the new regional project (RAF/9/059), recommend the establishment of diagnostic reference levels (DRLs) in Africa. In response to this recommendation, this project was designed to establish and utilise national DRLs of routine computed tomography (CT) examinations. These were done by estimating CT dose index and dose length product (DLP) from a minimum of 20 patient dose report of the most frequently used procedures using 75th percentile distribution of the median values. In all, 22 centres that formed 54% of all CT equipment in the country took part in this study. Additionally, a total of 2156 adult patients dose report were randomly selected, with a percentage distribution of 60, 12, 21 and 7% for head, chest, abdomen-pelvis and lumber spine, respectively. The established DRL for volume CT dose index were 60.0, 15.7, 20.5 and 23.8 mGy for head, chest, abdomen-pelvis and lumber spine, respectively. While the established DRL for DLP were 962.9, 1102.8, 1393.5 and 824.6 mGy-cm for head, chest, abdomen-pelvis, and lumber spine, respectively. These preliminary results were comparable with data from 16 other African countries, European Commission and the International Commission on Radiological Protection. Hence, this study would serve as a baseline for the establishment of a more generalised regional and national adult DRLs for Africa and other developing countries.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Adulto , Gana , Níveis de Referência de Diagnóstico , Masculino , Feminino , Cabeça/diagnóstico por imagem , Pessoa de Meia-Idade , Valores de Referência
4.
Clin Imaging ; 108: 110081, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340435

RESUMO

We compared image quality of head and neck CT angiography (CTA) obtained with a photon-counting detector CT (PCD-CT), including virtual monoenergetic images and polyenergetic reconstructions, and conventional energy-integrating detectors CT (EID-CT) in three patients. PCD-CT monoenergetic reconstructions at 70 keV and lower provided excellent image quality, with improved signal-to-noise and contrast-to-noise compared to EID-CT and PCD-CT polyenergetic reconstructions. PCD-CT may enable radiation dose and iodinated contrast dose reduction for cerebrovascular imaging.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Humanos , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Imagens de Fantasmas
5.
Phys Med Biol ; 69(5)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38306964

RESUMO

Objective. Electroencephalograms (EEGs) are often used to monitor brain activity. Several source localization methods have been proposed to estimate the location of brain activity corresponding to EEG readings. However, only a few studies evaluated source localization accuracy from measured EEG using personalized head models in a millimeter resolution. In this study, based on a volume conductor analysis of a high-resolution personalized human head model constructed from magnetic resonance images, a finite difference method was used to solve the forward problem and to reconstruct the field distribution.Approach. We used a personalized segmentation-free head model developed using machine learning techniques, in which the abrupt change of electrical conductivity occurred at the tissue interface is suppressed. Using this model, a smooth field distribution was obtained to address the forward problem. Next, multi-dipole fitting was conducted using EEG measurements for each subject (N= 10 male subjects, age: 22.5 ± 0.5), and the source location and electric field distribution were estimated.Main results.For measured somatosensory evoked potential for electrostimulation to the wrist, a multi-dipole model with lead field matrix computed with the volume conductor model was found to be superior than a single dipole model when using personalized segmentation-free models (6/10). The correlation coefficient between measured and estimated scalp potentials was 0.89 for segmentation-free head models and 0.71 for conventional segmented models. The proposed method is straightforward model development and comparable localization difference of the maximum electric field from the target wrist reported using fMR (i.e. 16.4 ± 5.2 mm) in previous study. For comparison, DUNEuro based on sLORETA was (EEG: 17.0 ± 4.0 mm). In addition, somatosensory evoked magnetic fields obtained by Magnetoencephalography was 25.3 ± 8.5 mm using three-layer sphere and sLORETA.Significance. For measured EEG signals, our procedures using personalized head models demonstrated that effective localization of the somatosensory cortex, which is located in a non-shallower cortex region. This method may be potentially applied for imaging brain activity located in other non-shallow regions.


Assuntos
Mapeamento Encefálico , Eletroencefalografia , Masculino , Humanos , Adulto Jovem , Adulto , Mapeamento Encefálico/métodos , Eletroencefalografia/métodos , Magnetoencefalografia/métodos , Imageamento por Ressonância Magnética , Couro Cabeludo , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Modelos Neurológicos , Cabeça/diagnóstico por imagem , Cabeça/fisiologia
6.
Sensors (Basel) ; 24(4)2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38400344

RESUMO

Magnetoelectric (ME) magnetic field sensors are novel sensing devices of great interest in the field of biomagnetic measurements. We investigate the influence of magnetic crosstalk and the linearity of the response of ME sensors in different array and excitation configurations. To achieve this aim, we introduce a combined multiscale 3D finite-element method (FEM) model consisting of an array of 15 ME sensors and an MRI-based human head model with three approximated compartments of biological tissues for skin, skull, and white matter. A linearized material model at the small-signal working point is assumed. We apply homogeneous magnetic fields and perform inhomogeneous magnetic field excitation for the ME sensors by placing an electric point dipole source inside the head. Our findings indicate significant magnetic crosstalk between adjacent sensors leading down to a 15.6% lower magnetic response at a close distance of 5 mm and an increasing sensor response with diminishing crosstalk effects at increasing distances up to 5 cm. The outermost sensors in the array exhibit significantly less crosstalk than the sensors located in the center of the array, and the vertically adjacent sensors exhibit a stronger crosstalk effect than the horizontally adjacent ones. Furthermore, we calculate the ratio between the electric and magnetic sensor responses as the sensitivity value and find near-constant sensitivities for each sensor, confirming a linear relationship despite magnetic crosstalk and the potential to simulate excitation sources and sensor responses independently.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Humanos , Simulação por Computador , Cabeça/diagnóstico por imagem
7.
J Magn Reson ; 360: 107636, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38377783

RESUMO

Very-low field (VLF) magnetic resonance imaging (MRI) offers advantages in term of size, weight, cost, and the absence of robust shielding requirements. However, it encounters challenges in maintaining a high signal-to-noise ratio (SNR) due to low magnetic fields (below 100 mT). Developing a close-fitting radio frequency (RF) receive coil is crucial to improve the SNR. In this study, we devised and optimized a helmet-shaped dual-channel RF receive coil tailored for brain imaging at a magnetic field strength of 54 mT (2.32 MHz). The methodology integrates the inverse boundary element method (IBEM) to formulate initial coil structures and wiring patterns, followed by optimization through introducing regularization terms. This approach frames the design process as an inverse problem, ensuring a close fit to the head contour. Combining theoretical optimization with physical measurements of the coil's AC resistance, we identified the optimal loop count for both axial and radial coils as nine and eight loops, respectively. The effectiveness of the designed dual-channel coil was verified through the imaging of a CuSO4 phantom and a healthy volunteer's brain. Notably, the in-vivo images exhibited an approximate 16-25 % increase in SNR with poorer B1 homogeneity compared to those obtained using single-channel coils. The high-quality images achieved by T1, T2-weighted, and fluid-attenuated inversion-recovery (FLAIR) protocols enhance the diagnostic potential of VLF MRI, particularly in cases of cerebral stroke and trauma patients. This study underscores the adaptability of the design methodology for the customization of RF coil structures in alignment with individual imaging requirements.


Assuntos
Encéfalo , Dispositivos de Proteção da Cabeça , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cabeça/diagnóstico por imagem , Razão Sinal-Ruído , Imagens de Fantasmas , Desenho de Equipamento , Ondas de Rádio , Neuroimagem
8.
Dent Clin North Am ; 68(2): 375-391, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38417996

RESUMO

This article provides an overview of the soft tissue calcifications in the head and neck region as noted on dental imaging, with particular focus on the radiographic appearance of these entities..


Assuntos
Tomografia Computadorizada de Feixe Cônico , Pescoço , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Pescoço/diagnóstico por imagem , Cabeça/diagnóstico por imagem
9.
HNO ; 72(3): 154-160, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38353674

RESUMO

BACKGROUND: Training in clinical ultrasound has become highly relevant for working as an otorhinolaryngologist. While there is a high demand for standardized and certified training courses, until recently, there was no possibility to attend web-based and exclusively virtual head and neck ultrasound courses certified by the Deutsche Gesellschaft für Ultraschall in der Medizin (DEGUM; German Society for Ultrasound in Medicine). OBJECTIVE: The aim of this study was to provide a qualitative and semi-quantitative analysis of the first purely virtual DEGUM-certified head and neck ultrasound courses. MATERIALS AND METHODS: In 2021, three purely web-based DEGUM-certified head and neck ultrasound courses were carried out and then qualitatively analyzed using questionnaires including an examination. RESULTS: The purely virtual implementation of head and neck ultrasound courses proved to be a viable alternative to the conventional course format, with a high level of acceptance among the participants. The lack of practice among the participants remains a relevant criticism. CONCLUSION: A more dominant role of web-based and remote ultrasound training is likely and should be considered as an alternative depending on existing conditions. Nevertheless, acquisition of practical sonographic skills remains a major hurdle if courses are purely digital.


Assuntos
Cabeça , Medicina , Humanos , Ultrassonografia , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Currículo
10.
Phys Med ; 118: 103215, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38224662

RESUMO

PURPOSE: Organ dose evaluation is important for optimizing cone beam computed tomography (CBCT) scan protocols. However, an evaluation method for various CBCT scanners is yet to be established. In this study, we developed scanner-independent conversion coefficients to estimate organ doses using appropriate peak dose (f(0)) indices. METHODS: This study included various scanners (angiography scanners and linear accelerators) and protocols for the head and body (thorax, abdomen, and pelvis) scan regions. f(0) was measured at five conventional positions (center position (f(0)c) and four peripheral positions (f(0)p) at 90° intervals) in the CT dose index (CTDI) phantom. To identify appropriate measurement positions for organ dose estimation, various f(0) indices were considered. Organ doses were measured by using optically stimulated luminescence dosimeters positioned in an anthropomorphic phantom. Thereafter, the conversion coefficients were calculated from each obtained f(0) value and organ or tissue dose using a linear fit for all scanners, and the coefficient of variation (CV) of the conversion coefficients was calculated for each organ or tissue. The f(0) index with the minimum CV value was proposed as the appropriate index. RESULTS: The appropriate f(0) index was determined as f(0)c for the body region and a maximum of four f(0)p values for the head region. Using the proposed conversion coefficients based on the appropriate f(0) index, the organ/tissue doses were well estimated with a mean error of 14.2% across all scanners and scan regions. CONCLUSIONS: The proposed scanner-independent coefficients are useful for organ dose evaluation using CBCT scanners.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cabeça , Doses de Radiação , Método de Monte Carlo , Tomografia Computadorizada de Feixe Cônico/métodos , Cabeça/diagnóstico por imagem , Imagens de Fantasmas , Radiometria/métodos
11.
HNO ; 72(2): 76-82, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-38051313

RESUMO

BACKGROUND: Ultrasound is an important imaging method in the head and neck area. It is readily available, dynamic, inexpensive, and does not involve radiation exposure. Interventions in the complex head and neck anatomy require good orientation, which is supported by navigation systems. OBJECTIVE: This work aimed to develop a new ultrasound-controlled navigation system for taking biopsies of small target structures in the head and neck region. METHODS: A neck phantom with sonographically detectable masses (size: 8-10 mm) was constructed. These were automatically segmented using a ResNet-50-based deep neural network. The ultrasound scanner was equipped with an individually manufactured tracking tool. RESULTS: The positions of the ultrasound device, the masses, and a puncture needle were recorded in the world coordinate system. In 8 out of 10 cases, an 8­mm mass was hit. In a special evaluation phantom, the average deviation was calculated to be 2.5 mm. The tracked biopsy needle is aligned and navigated to the masses by auditory feedback. CONCLUSION: Outstanding advantages compared to conventional navigation systems include renunciation of preoperative tomographic imaging, automatic three-dimensional real-time registration that considers intraoperative tissue displacements, maintenance of the surgeon's optical axis at the surgical site without having to look at a navigation monitor, and working freely with both hands without holding the ultrasound scanner during biopsy taking. The described functional model can also be used in open head and neck surgery.


Assuntos
Cirurgia Assistida por Computador , Cirurgia Assistida por Computador/métodos , Ultrassonografia , Pescoço/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Biópsia
12.
Magn Reson Med ; 91(3): 1268-1280, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38009927

RESUMO

PURPOSE: The aim of this work is to evaluate a new eight-channel transceiver (TxRx) coaxial dipole array for imaging of the human head at 9.4T developed to improve specific absorption rate (SAR) performance, and provide for a more compact and robust alternative to the state-of-the art dipole arrays. METHODS: First, the geometry of a single coaxial element was optimized to minimize peak SAR and sensitivity to the load variation. Next, a multi-tissue voxel model was used to numerically simulate a TxRx array coil that consisted of eight coaxial dipoles with the optimal configuration. Finally, we compared the developed array to other human head dipole arrays. Results of numerical simulations were verified on a bench and in the scanner including in vivo measurements on a healthy volunteer. RESULTS: The developed eight-element coaxial dipole TxRx array coil showed up to 1.1times higher SAR-efficiency than a similar in geometry folded-end and fractionated dipole array while maintaining whole brain coverage and low sensitivity of the resonance frequency to variation in the head size. CONCLUSION: As a proof of concept, we developed and constructed a prototype of a 9.4T (400 MHz) human head array consisting of eight TxRx coaxial dipoles. The developed array improved SAR-efficiency and provided for a more compact and robust alternative to the folded-end dipole design. To the best of our knowledge, this is the first example of using coaxial dipoles for human head MRI at ultra-high field.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Desenho de Equipamento , Cabeça/diagnóstico por imagem
13.
Magn Reson Med ; 91(3): 1209-1224, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37927216

RESUMO

PURPOSE: We model the performance of parallel transmission (pTx) arrays with 8, 16, 24, and 32 channels and varying loop sizes built on a close-fitting helmet for brain imaging at 7 T and compare their local specific absorption rate (SAR) and flip-angle performances to that of birdcage coil (used as a baseline) and cylindrical 8-channel and 16-channel pTx coils (single-row and dual-row). METHODS: We use the co-simulation approach along with MATLAB scripting for batch-mode simulation of the coils. For each coil, we extracted B1 + maps and SAR matrices, which we compressed using the virtual observation points algorithm, and designed slice-selective RF shimming pTx pulses with multiple local SAR and peak power constraints to generate L-curves in the transverse, coronal, and sagittal orientations. RESULTS: Helmet designs outperformed cylindrical pTx arrays at a constant number of channels in the flip-angle uniformity at a constant local SAR metric: up to 29% for 8-channel arrays, and up to 34% for 16-channel arrays, depending on the slice orientation. For all helmet arrays, increasing the loop diameter led to better local SAR versus flip-angle uniformity tradeoffs, although this effect was more pronounced for the 8-channel and 16-channel systems than the 24-channel and 32-channel systems, as the former have more limited degrees of freedom and therefore benefit more from loop-size optimization. CONCLUSION: Helmet pTx arrays significantly outperformed cylindrical arrays with the same number of channels in local SAR and flip-angle uniformity metrics. This improvement was especially pronounced for non-transverse slice excitations. Loop diameter optimization for helmets appears to favor large loops, compatible with nearest-neighbor decoupling by overlap.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Encéfalo/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Imagens de Fantasmas
14.
Ultrasound Obstet Gynecol ; 63(2): 251-257, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37610831

RESUMO

OBJECTIVES: To evaluate the relationship between the attitude of the fetal head quantified by means of the chin-to-chest angle (CCA) in fetuses in occiput posterior (OP) position at the beginning of the second stage of labor, and persistent OP position at birth. METHODS: This was a single-center, prospective observational study conducted at the University Hospital of Parma, Parma, Italy. We included singleton pregnancies at term with fetuses in the OP position at the beginning of the second stage of labor. The fetal head position, station by means of angle of progression and head-to-perineum distance, and attitude by means of CCA were assessed using transabdominal or transperineal ultrasound. The primary outcome was persistent OP position at birth. RESULTS: Between January and July 2022, 76 women were included in the study. There were 48 (63.2%) spontaneous rotations of the fetal head and spontaneous vaginal delivery occurred in all. Among the 28 (36.8%) fetuses that did not rotate spontaneously into an occiput anterior position, eight (28.6%) had a spontaneous vaginal delivery, while operative vaginal delivery and Cesarean delivery was performed in 11 (39.3%) and nine (32.1%) cases, respectively. Multivariable logistic regression analysis showed that the CCA (adjusted odds ratio (aOR), 2.15 (95% CI, 1.22-3.78); P = 0.008) and nulliparity (aOR, 0.20 (95% CI, 0.06-0.76); P = 0.02) were associated independently with persistent OP position at birth. Moreover, the CCA showed an area under the receiver-operating-characteristics curve of 0.69 (95% CI, 0.56-0.82); P = 0.005) for the prediction of persistent OP position. The optimal cut-off value of the CCA was 36.5°, and was associated with a sensitivity of 0.82 (95% CI, 0.63-0.94), specificity of 0.50 (95% CI, 0.35-0.65), positive predictive value of 0.49 (95% CI, 0.34-0.64), negative predictive value of 0.83 (95% CI, 0.64-0.94), positive likelihood ratio of 1.64 (95% CI, 1.18-2.29) and negative likelihood ratio of 0.36 (95% CI, 0.15-0.83). CONCLUSIONS: Our data show that, within a population of women with fetal OP position at the beginning of the second stage of labor, the sonographic fetal head attitude measured by means of the CCA might help in the identification of fetuses at risk of persistent OP position. Such findings can be useful for patient counseling when OP position is diagnosed at full cervical dilatation. Further studies should investigate if the CCA might select patients who may benefit from manual rotation of the fetal head. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Feto , Apresentação no Trabalho de Parto , Recém-Nascido , Gravidez , Feminino , Humanos , Estudos Prospectivos , Feto/diagnóstico por imagem , Segunda Fase do Trabalho de Parto , Ultrassonografia Pré-Natal , Parto Obstétrico , Cabeça/diagnóstico por imagem
15.
Int J Gynaecol Obstet ; 164(1): 131-139, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37401541

RESUMO

OBJECTIVE: To evaluate the level of agreement between ultrasound measurements to evaluate fetal head position and progress of labor by attending midwives and obstetricians after appropriate training. METHODS: In this prospective study, women in the first stage of labor giving birth to a single baby in cephalic presentation at our Obstetric Unit between March 2018 and December 2019 were invited to participate; 109 women agreed. Transperineal and transabdominal ultrasound was independently performed by a trained midwife and an obstetrician. Two paired measurements were available for comparisons in 107 cases for the angle of progression (AoP), in 106 cases for the head-to-perineum distance (HPD), in 97 cases for the cervical dilatation (CD), and in 79 cases for the fetal head position. RESULTS: We found a good correlation between the AoP measured by obstetricians and midwives (intra-class correlation coefficient [ICC] = 0.85; 95% confidence interval [CI] 0.80-0.89). There was a moderate correlation between the HPD (ICC = 0.75; 95% CI 0.68-0.82). There was a very good correlation between the CD measured (ICC = 0.94; 95% CI 0.91-0.96). There was a very good level of agreement in the classification of the fetal head position (Cohen's κ = 0.89; 95% CI 0.80-0.98). CONCLUSIONS: Ultrasound assessment of fetal head position and progress of labor can effectively be performed by attending midwives without previous experience in ultrasound.


Assuntos
Tocologia , Gravidez , Feminino , Humanos , Obstetra , Estudos Prospectivos , Feto , Apresentação no Trabalho de Parto , Ultrassonografia Pré-Natal , Cabeça/diagnóstico por imagem
16.
Magn Reson Med ; 91(1): 190-204, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37794847

RESUMO

PURPOSE: Neurovascular MRI suffers from a rapid drop in B1 + into the neck when using transmit head coils at 7 T. One solution to improving B1 + magnitude in the major feeding arteries in the neck is to use custom RF shims on parallel-transmit head coils. However, calculating such shims requires robust multichannel B1 + maps in both the head and the neck, which is challenging due to low RF penetration into the neck, limited dynamic range of multichannel B1 + mapping techniques, and B0 sensitivity. We therefore sought a robust, large-dynamic-range, parallel-transmit field mapping protocol and tested whether RF shimming can improve carotid artery B1 + magnitude in practice. METHODS: A pipeline is presented that combines B1 + mapping data acquired using circularly polarized (CP) and CP2-mode RF shims at multiple voltages. The pipeline was evaluated by comparing the predicted and measured B1 + for multiple random transmit shims, and by assessing the ability of RF shimming to increase B1 + in the carotid arteries. RESULTS: The proposed method achieved good agreement between predicted and measured B1 + in both the head and the neck. The B1 + magnitude in the carotid arteries can be increased by 43% using tailored RF shims or by 37% using universal RF shims, while also improving the RF homogeneity compared with CP mode. CONCLUSION: B1 + in the neck can be increased using RF shims calculated from multichannel B1 + maps in both the head and the neck. This can be achieved using universal phase-only RF shims, facilitating easy implementation in existing sequences.


Assuntos
Cabeça , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Ondas de Rádio , Imagens de Fantasmas
17.
Artigo em Inglês | MEDLINE | ID: mdl-38083025

RESUMO

CT scans of the head and neck have multiple clinical uses, and simulating deformation of these CT scans allows for predicting patient motion and data augmentation for machine-learning methods. Current methods for creating patient-derived deformed CT scans require multiple scans or use unrealistic head and neck motion. This paper describes the CTHeadDeformation software package which allows for realistic synthetic deformation of head and neck CT scans for small amounts of motion. CTHeadDeformation is a python-based package that uses a kinematics-based approach using anatomical landmarks, and rigid/non-rigid registration to create a realistic patient-derived deformed CT scan. CTHeadDeformation is also designed for simple clinical implementation. The CTHeadDeformation software package was demonstrated on a head and neck CT scan of one patient. The CT scan was deformed in the anterior-posterior, superior-inferior, and left-right directions. Internal organ motion and more complex combination motions were also simulated. The results showed the patient's CT scan was able to be deformed in a way that preserved the shape and location of the anatomy.Clinical Relevance- This method allows for the realistic simulation of head and neck motion in CT scans. Clinical applications including simulating how patient motion affects radiation therapy treatment effectiveness. The CTHeadDeformation software can also be used to train machine-learning networks that are robust to patient motion, or to generate ground truth images for imaging or segmentation grand challenges.


Assuntos
Cabeça , Processamento de Imagem Assistida por Computador , Humanos , Fenômenos Biomecânicos , Processamento de Imagem Assistida por Computador/métodos , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X
18.
Phys Med Biol ; 68(24)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-37983915

RESUMO

Objective.Head motion correction (MC) is an essential process in brain positron emission tomography (PET) imaging. We have used the Polaris Vicra, an optical hardware-based motion tracking (HMT) device, for PET head MC. However, this requires attachment of a marker to the subject's head. Markerless HMT (MLMT) methods are more convenient for clinical translation than HMT with external markers. In this study, we validated the United Imaging Healthcare motion tracking (UMT) MLMT system using phantom and human point source studies, and tested its effectiveness on eight18F-FPEB and four11C-LSN3172176 human studies, with frame-based region of interest (ROI) analysis. We also proposed an evaluation metric, registration quality (RQ), and compared it to a data-driven evaluation method, motion-corrected centroid-of-distribution (MCCOD).Approach.UMT utilized a stereovision camera with infrared structured light to capture the subject's real-time 3D facial surface. Each point cloud, acquired at up to 30 Hz, was registered to the reference cloud using a rigid-body iterative closest point registration algorithm.Main results.In the phantom point source study, UMT exhibited superior reconstruction results than the Vicra with higher spatial resolution (0.35 ± 0.27 mm) and smaller residual displacements (0.12 ± 0.10 mm). In the human point source study, UMT achieved comparable performance as Vicra on spatial resolution with lower noise. Moreover, UMT achieved comparable ROI values as Vicra for all the human studies, with negligible mean standard uptake value differences, while no MC results showed significant negative bias. TheRQevaluation metric demonstrated the effectiveness of UMT and yielded comparable results to MCCOD.Significance.We performed an initial validation of a commercial MLMT system against the Vicra. Generally, UMT achieved comparable motion-tracking results in all studies and the effectiveness of UMT-based MC was demonstrated.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Cabeça/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Movimento (Física) , Imagens de Fantasmas , Algoritmos , Movimento
19.
Medicine (Baltimore) ; 102(47): e35855, 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38013270

RESUMO

RATIONALE: Hemangioma is a common benign disease in clinical practice, but it is rare to find a giant hemangioma in the fetal period. PATIENT CONCERNS: Here, we report a case of a giant hemangioma of the fetal head and neck measuring approximately 10.1 × 6.5 cm. DIAGNOSES: At first, only ultrasonography was used to diagnose the suspected hemangioma. The pregnant woman refused to undergo further testing and requested induction of labor, after which the tumor was finally sent for pathological examination to confirm hemangioma. INTERVENTIONS AND OUTCOMES: Additionally, the fetus developed severe edema (fluid accumulation in the thoracic, abdominal, and pericardial cavities), which can be fatal to the fetus. Finally, the mother refused to continue the pregnancy and underwent induction of labor with rivanol. LESSONS: Most hemangiomas are small and asymptomatic. Giant hemangiomas are rare and associated with a variety of maternal and fetal complications. Therefore, this article aims to summarize the knowledge related to hemangioma through this case, strengthen doctors' understanding of this disease, and bring the attention of pregnant women to this disease to ensure early diagnosis and treatment and prevent a poor prognosis.


Assuntos
Hemangioma Cavernoso , Hemangioma , Humanos , Feminino , Gravidez , Hemangioma/diagnóstico por imagem , Hemangioma/patologia , Pescoço/patologia , Feto/patologia , Cabeça/diagnóstico por imagem , Cabeça/patologia
20.
Radiol Phys Technol ; 16(4): 552-559, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37819445

RESUMO

Attenuation correction (AC) is essential for quantitative positron emission tomography (PET) images. Attenuation coefficient maps (µ-maps) are usually generated from computed tomography (CT) images when PET-CT combined systems are used. If CT has been performed prior to PET imaging, pre-acquired CT can be used for brain PET AC, because the human head is almost rigid. This pre-acquired CT-based AC approach is suitable for stand-alone brain-dedicated PET, such as VRAIN (ATOX Co. Ltd., Tokyo, Japan). However, the headrest of PET is different from the headrest in pre-acquired CT images, which may degrade the PET image quality. In this study, we prepared three different types of µ-maps: (1) based on the pre-acquired CT, where namely the headrest is different from the PET system (µ-map-diffHr); (2) manually removing the headrest from the pre-acquired CT (µ-map-noHr); and (3) artificially replacing the headrest region with the headrest of the PET system (µ-map-sameHr). Phantom images by VRAIN using each µ-map were investigated for uniformity, noise, and quantitative accuracy. Consequently, only the uniformity of the images using µ-map-diffHr was out of the acceptance criteria. We then proposed an automated method for removing the headrest from pre-acquired CT images. In comparisons of standardized uptake values in nine major brain regions from the 18F-fluoro-2-deoxy-D-glucose-PET of 10 healthy volunteers, no significant differences were found between the µ-map-noHr and the µ-map-sameHr. In conclusion, pre-acquired CT-based AC with automated headrest removal is useful for brain-dedicated PET such as VRAIN.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Encéfalo/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos